Dil:

Plastics – Determination of the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of thermoplastics


Purpose: The determination of the melt mass-flow rate (MFR) and the melt volume-flow rate (MVR) of thermoplastic materials under specified conditions of temperature and load. Procedure A is a mass-measurement method. Procedure B is a displacement- measurement method. Normally, the test conditions for measurement of melt flow rate are specified in the material standard with a reference to this document.

Standards:

ASTM D1238, ISO 1133-1 & 2

Measured Properties

  • Measurement of Melt Flow Rate (MFR) in grams per 10 minutes

Plastics & Rubber, vulcanized or thermoplastic  – Methods for determining the density of non-cellular and cellular plastics & Rubber, vulcanized or thermoplastic  

 

Purpose: Density measurement of for quality control, ensuring material uniformity, and monitoring structural or compositional variations

Standards for non-cellular plastics

ASTM D792, ISO 1183

 

Standards for cellular plastics

 

ASTM D1622, ISO 845, ASTM D3575

 

 Standards for Rubber, vulcanized or thermoplastic

ISO 2781, ASTM D297

 

Measured Properties

  • Determination of the material density in grams per cubic centimeter (g/cm³) or kilograms per cubic meter (kg/m³)