Language:

Thermogravimetric Analysis (TGA) Test 

Purpose: Determination of weight changes in polymers upon heating to evaluate thermal stability, decomposition temperature, and the content of additives and fillers.

Standards: ASTM E1131, ASTM D3850, ISO 11358-1 & 2, DIN 51006

Measured Properties

  • Weight Loss / Mass Change:
    Quantification of the sample’s mass reduction or gain under heating or controlled conditions.
    Units: % or g
  • Onset Decomposition Temperature (Tonset):
    Temperature at which the sample begins thermal decomposition or noticeable mass loss.
    Units: °C
  • Peak Decomposition Temperature / Tmax:
    Temperature corresponding to the maximum rate of mass loss during decomposition.
    Units: °C
  • Stepwise Decomposition / Multi-step Decomposition:
    Identification of successive thermal degradation stages of the polymer matrix, additives, or fillers.
  • Residue / Char Content:
    Mass remaining after complete thermal decomposition, typically used to evaluate mineral content, fillers, or residual carbon.
  • Rate of Mass Loss / dm/dt:
    Derived from the DTG (Derivative Thermogravimetry) curve, providing detailed

Plastics – Differential scanning calorimetry (DSC)

Purpose: Differential scanning calorimetry (DSC) methods are used for the thermal analysis of polymers and polymer blends.

Standards: ASTM D3418, ISO 11357

Measured Properties

Differential scanning calorimetry (DSC) methods are used for the thermal analysis of polymers and polymer blends, such as:

  • Thermoplastics (polymers, molding compounds and other molding materials, with or without fillers, fibers or reinforcements),
  • Thermosets (uncured or cured materials, with or without fillers, fibers or reinforcements), and
  • Physical transitions (glass transition, phase transitions such as melting and crystallization,
    • Polymorphic transitions, etc.),
  • Chemical reactions (polymerization, crosslinking and curing of elastomers and thermosets, etc.),
  • The stability to oxidation, and
  • The heat capacity

Plastics – Thermoplastic materials – Determination of Vicat softening temperature (VST)

Purpose: The determination of the Vicat softening temperature (VST) of thermoplastic materials:

  • Method A50 using a force of 10 N and a heating rate of 50 °C/h
    • Method B50 using a force of 50 N and a heating rate of 50 °C/h
    • Method A120 using a force of 10 N and a heating rate of 120 °C/h
    • Method B120 using a force of 50 N and a heating rate of 120 °C/h

Standards: ASTM D1525, ISO 306

Measured Properties

  • Determination of the Vicat softening temperature (VST) of thermoplastic materials

Plastics – Determination of temperature of deflection under load (HDT Test)

Purpose: The determination of the temperature of deflection under load (flexural stress under three-point loading) of plastics. Different types of test specimen and different constant loads are defined to suit different types of material.

Standards: ASTM D648, ISO 75-1 & 2 & 3

Measured Properties

determination of the temperature of deflection under load (flexural stress under three-point loading)of plastics