{"id":3146,"date":"2026-06-28T12:31:20","date_gmt":"2026-06-28T12:31:20","guid":{"rendered":"https:\/\/rms-labgroup.com\/?page_id=3146"},"modified":"2026-07-19T07:06:05","modified_gmt":"2026-07-19T07:06:05","slug":"fatigue","status":"publish","type":"page","link":"https:\/\/rms-labgroup.com\/tr\/laboratories\/mechanical-testing-laboratory\/fatigue\/","title":{"rendered":"Fatigue"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"3146\" class=\"elementor elementor-3146\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5e32398 e-flex e-con-boxed e-con e-parent\" data-id=\"5e32398\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8d3952b elementor-widget elementor-widget-gallery\" data-id=\"8d3952b\" data-element_type=\"widget\" data-settings=\"{&quot;columns&quot;:2,&quot;gap&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:6,&quot;sizes&quot;:[]},&quot;columns_tablet&quot;:1,&quot;lazyload&quot;:&quot;yes&quot;,&quot;gallery_layout&quot;:&quot;grid&quot;,&quot;columns_mobile&quot;:1,&quot;gap_tablet&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:10,&quot;sizes&quot;:[]},&quot;gap_mobile&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:10,&quot;sizes&quot;:[]},&quot;link_to&quot;:&quot;file&quot;,&quot;aspect_ratio&quot;:&quot;3:2&quot;,&quot;overlay_background&quot;:&quot;yes&quot;,&quot;content_hover_animation&quot;:&quot;fade-in&quot;}\" data-widget_type=\"gallery.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-gallery__container\">\n\t\t\t\t\t\t\t<a class=\"e-gallery-item elementor-gallery-item elementor-animated-content\" href=\"https:\/\/rms-labgroup.com\/wp-content\/uploads\/2026\/06\/Mechanical-Testing-Laboratory5.jpg\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-slideshow=\"8d3952b\" data-elementor-lightbox-title=\"Mechanical Testing Laboratory5\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6NDUyLCJ1cmwiOiJodHRwczpcL1wvcm1zLWxhYmdyb3VwLmNvbVwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNlwvMDZcL01lY2hhbmljYWwtVGVzdGluZy1MYWJvcmF0b3J5NS5qcGciLCJzbGlkZXNob3ciOiI4ZDM5NTJiIn0%3D\">\n\t\t\t\t\t<div class=\"e-gallery-image elementor-gallery-item__image\" data-thumbnail=\"https:\/\/rms-labgroup.com\/wp-content\/uploads\/2026\/06\/Mechanical-Testing-Laboratory5.jpg\" data-width=\"505\" data-height=\"322\" aria-label=\"\" role=\"img\" ><\/div>\n\t\t\t\t\t\t\t\t\t\t\t<div class=\"elementor-gallery-item__overlay\"><\/div>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t<a class=\"e-gallery-item elementor-gallery-item elementor-animated-content\" href=\"https:\/\/rms-labgroup.com\/wp-content\/uploads\/2026\/06\/Mechanical-Testing-Laboratory6.jpg\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-slideshow=\"8d3952b\" data-elementor-lightbox-title=\"Mechanical Testing Laboratory6\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6NDUzLCJ1cmwiOiJodHRwczpcL1wvcm1zLWxhYmdyb3VwLmNvbVwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNlwvMDZcL01lY2hhbmljYWwtVGVzdGluZy1MYWJvcmF0b3J5Ni5qcGciLCJzbGlkZXNob3ciOiI4ZDM5NTJiIn0%3D\">\n\t\t\t\t\t<div class=\"e-gallery-image elementor-gallery-item__image\" data-thumbnail=\"https:\/\/rms-labgroup.com\/wp-content\/uploads\/2026\/06\/Mechanical-Testing-Laboratory6.jpg\" data-width=\"504\" data-height=\"367\" aria-label=\"\" role=\"img\" ><\/div>\n\t\t\t\t\t\t\t\t\t\t\t<div class=\"elementor-gallery-item__overlay\"><\/div>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7b00069 elementor-widget__width-initial elementor-widget-mobile__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"7b00069\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p><b>Rotating Bending Fatigue Test<\/b><\/p><p>The rotary bending fatigue test evaluates the fatigue behavior of materials under cyclic bending stress. A rotating specimen is subjected to a constant bending moment, generating alternating tensile and compressive stresses. The test is used to determine fatigue life, endurance limit, and S\u2013N curves, and is widely applied for durability assessment and design validation of rotating components such as shafts, axles, springs, and transmission parts.<\/p><p>Standard: ISO 1143<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Rotating Bending Fatigue Test The rotary bending fatigue test evaluates the fatigue behavior of materials under cyclic bending stress. A rotating specimen is subjected to a constant bending moment, generating alternating tensile and compressive stresses. The test is used to determine fatigue life, endurance limit, and S\u2013N curves, and is widely applied for durability assessment [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":444,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-3146","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.0 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Fatigue - RMS Lab Group<\/title>\n<meta name=\"robots\" content=\"noindex, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<meta property=\"og:locale\" content=\"tr_TR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Fatigue - RMS Lab Group\" \/>\n<meta property=\"og:description\" content=\"Rotating Bending Fatigue Test The rotary bending fatigue test evaluates the fatigue behavior of materials under cyclic bending stress. A rotating specimen is subjected to a constant bending moment, generating alternating tensile and compressive stresses. The test is used to determine fatigue life, endurance limit, and S\u2013N curves, and is widely applied for durability assessment [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/rms-labgroup.com\/tr\/laboratories\/mechanical-testing-laboratory\/fatigue\/\" \/>\n<meta property=\"og:site_name\" content=\"RMS Lab Group\" \/>\n<meta property=\"article:modified_time\" content=\"2026-07-19T07:06:05+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/rms-labgroup.com\\\/laboratories\\\/mechanical-testing-laboratory\\\/fatigue\\\/\",\"url\":\"https:\\\/\\\/rms-labgroup.com\\\/laboratories\\\/mechanical-testing-laboratory\\\/fatigue\\\/\",\"name\":\"Fatigue - RMS Lab Group\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/rms-labgroup.com\\\/tr\\\/#website\"},\"datePublished\":\"2026-06-28T12:31:20+00:00\",\"dateModified\":\"2026-07-19T07:06:05+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/rms-labgroup.com\\\/laboratories\\\/mechanical-testing-laboratory\\\/fatigue\\\/#breadcrumb\"},\"inLanguage\":\"tr\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/rms-labgroup.com\\\/laboratories\\\/mechanical-testing-laboratory\\\/fatigue\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/rms-labgroup.com\\\/laboratories\\\/mechanical-testing-laboratory\\\/fatigue\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/rms-labgroup.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Laboratories\",\"item\":\"https:\\\/\\\/rms-labgroup.com\\\/laboratories\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"mechanical Testing\",\"item\":\"https:\\\/\\\/rms-labgroup.com\\\/laboratories\\\/mechanical-testing-laboratory\\\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Fatigue\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/rms-labgroup.com\\\/tr\\\/#website\",\"url\":\"https:\\\/\\\/rms-labgroup.com\\\/tr\\\/\",\"name\":\"RMS Lab Group\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/rms-labgroup.com\\\/tr\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/rms-labgroup.com\\\/tr\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"tr\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/rms-labgroup.com\\\/tr\\\/#organization\",\"name\":\"RMS Lab Group\",\"url\":\"https:\\\/\\\/rms-labgroup.com\\\/tr\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"tr\",\"@id\":\"https:\\\/\\\/rms-labgroup.com\\\/tr\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/rms-labgroup.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/ChatGPT_Image_Jun_11__2026__01_17_50_PM-removebg-preview-e1781432855823.png\",\"contentUrl\":\"https:\\\/\\\/rms-labgroup.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/ChatGPT_Image_Jun_11__2026__01_17_50_PM-removebg-preview-e1781432855823.png\",\"width\":500,\"height\":151,\"caption\":\"RMS Lab Group\"},\"image\":{\"@id\":\"https:\\\/\\\/rms-labgroup.com\\\/tr\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Fatigue - RMS Lab Group","robots":{"index":"noindex","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"og_locale":"tr_TR","og_type":"article","og_title":"Fatigue - RMS Lab Group","og_description":"Rotating Bending Fatigue Test The rotary bending fatigue test evaluates the fatigue behavior of materials under cyclic bending stress. A rotating specimen is subjected to a constant bending moment, generating alternating tensile and compressive stresses. The test is used to determine fatigue life, endurance limit, and S\u2013N curves, and is widely applied for durability assessment [&hellip;]","og_url":"https:\/\/rms-labgroup.com\/tr\/laboratories\/mechanical-testing-laboratory\/fatigue\/","og_site_name":"RMS Lab Group","article_modified_time":"2026-07-19T07:06:05+00:00","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/rms-labgroup.com\/laboratories\/mechanical-testing-laboratory\/fatigue\/","url":"https:\/\/rms-labgroup.com\/laboratories\/mechanical-testing-laboratory\/fatigue\/","name":"Fatigue - RMS Lab Group","isPartOf":{"@id":"https:\/\/rms-labgroup.com\/tr\/#website"},"datePublished":"2026-06-28T12:31:20+00:00","dateModified":"2026-07-19T07:06:05+00:00","breadcrumb":{"@id":"https:\/\/rms-labgroup.com\/laboratories\/mechanical-testing-laboratory\/fatigue\/#breadcrumb"},"inLanguage":"tr","potentialAction":[{"@type":"ReadAction","target":["https:\/\/rms-labgroup.com\/laboratories\/mechanical-testing-laboratory\/fatigue\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/rms-labgroup.com\/laboratories\/mechanical-testing-laboratory\/fatigue\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/rms-labgroup.com\/"},{"@type":"ListItem","position":2,"name":"Laboratories","item":"https:\/\/rms-labgroup.com\/laboratories\/"},{"@type":"ListItem","position":3,"name":"mechanical Testing","item":"https:\/\/rms-labgroup.com\/laboratories\/mechanical-testing-laboratory\/"},{"@type":"ListItem","position":4,"name":"Fatigue"}]},{"@type":"WebSite","@id":"https:\/\/rms-labgroup.com\/tr\/#website","url":"https:\/\/rms-labgroup.com\/tr\/","name":"RMS Lab Group","description":"","publisher":{"@id":"https:\/\/rms-labgroup.com\/tr\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/rms-labgroup.com\/tr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"tr"},{"@type":"Organization","@id":"https:\/\/rms-labgroup.com\/tr\/#organization","name":"RMS Lab Group","url":"https:\/\/rms-labgroup.com\/tr\/","logo":{"@type":"ImageObject","inLanguage":"tr","@id":"https:\/\/rms-labgroup.com\/tr\/#\/schema\/logo\/image\/","url":"https:\/\/rms-labgroup.com\/wp-content\/uploads\/2026\/06\/ChatGPT_Image_Jun_11__2026__01_17_50_PM-removebg-preview-e1781432855823.png","contentUrl":"https:\/\/rms-labgroup.com\/wp-content\/uploads\/2026\/06\/ChatGPT_Image_Jun_11__2026__01_17_50_PM-removebg-preview-e1781432855823.png","width":500,"height":151,"caption":"RMS Lab Group"},"image":{"@id":"https:\/\/rms-labgroup.com\/tr\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/rms-labgroup.com\/tr\/wp-json\/wp\/v2\/pages\/3146","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/rms-labgroup.com\/tr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/rms-labgroup.com\/tr\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/rms-labgroup.com\/tr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/rms-labgroup.com\/tr\/wp-json\/wp\/v2\/comments?post=3146"}],"version-history":[{"count":16,"href":"https:\/\/rms-labgroup.com\/tr\/wp-json\/wp\/v2\/pages\/3146\/revisions"}],"predecessor-version":[{"id":9057,"href":"https:\/\/rms-labgroup.com\/tr\/wp-json\/wp\/v2\/pages\/3146\/revisions\/9057"}],"up":[{"embeddable":true,"href":"https:\/\/rms-labgroup.com\/tr\/wp-json\/wp\/v2\/pages\/444"}],"wp:attachment":[{"href":"https:\/\/rms-labgroup.com\/tr\/wp-json\/wp\/v2\/media?parent=3146"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}